Enhancing endoscope performance with flexible circuits
There is significant momentum behind the adoption of flexible circuits in the medical field, driven by the growing demand for advanced catheter-based technologies. These solutions enable minimally invasive procedures across a wide range of applications, including ablation, electrophysiology studies, cardiac mapping and diagnostics, angioplasty, stent deployment, and beyond.
Flexible circuits are playing an increasingly important role in modern medical devices by improving precision, reliability, and functionality in space-constrained environments.
| ITEMS | MASS PRODUCTION |
|---|---|
| Layer | 1-6L |
| Thickness | Multi-layer board according to customer requirements |
| Single sided board: 0.065mm MIN | |
| Double-sided board: 0.125mm MIN | |
| Outline | Length: single/double/multi-layer: 1.45m MAX * |
| Width: single/double/multi-layer: 0.5mm - 0.8mm MIN * | |
| Multi-layer: 1.0mm MIN * | |
| *The data obtained from the average calculation according to the wiring of the product | |
| Options | Shield Film: (thickness: 16um, 20um) |
| FR4 (0.1-0.5mm) | |
| PI stiffener (0.075-0.225mm) | |
| Metallic stiffener (0.1-0.3mm) | |
| Min. Conductor Width & Spacing | Single and double sided circuit: 0.05mm |
| Multi-layered circuit: 0.075mm | |
| Alignment Tolerance Between Layers | 0.05mm |
| Conductor To Outline | Single and double sided circuit: >0.10mm |
| Multi-layer circuit: >0.15mm | |
| PAD To Outline | 0.2mm MIN |
| Min. Hole Size | Laser drill: Ø0.05mm |
| Mechanical drill PTH: Ø0.1mm | |
| Copper Plating Thickness | 10-15um (hole) |
| Min. Coverlay Openings | 0.50mm |
| Min. Coverlay Web | 0.30mm |
| Min. Solder Mask Opening | 0.20-0.30mm |
| Min. Solder Mask Web | 0.10mm |
| Max. Panel Size | ≤250*1500mm (single/double/multi-layer) |
| Final Finish | ENIG (NI:2-6um AU:0.05-0.09um) |
| Electroplated hard gold (NI:2-6um AU:0.1-1.0um) | |
| Electroplated soft gold (NI:2-6um AU:0.1-1.0um) | |
| Trim Method | Laser (outline<1mm) |
| Tooling (Outline>1mm)-- tooling costs ≥ $4k | |
| Impedence Requirement | Differential impedance: 100ohms+/-10% |
Features
PRECISION & RELIABILITY
Flexible circuits enhance catheter performance by delivering superior movement control, durability, and consistent operation during complex medical procedures. Their ability to maintain integrity under repeated flexing and in challenging anatomical environments helps physicians achieve greater procedural accuracy and safety.
MINIATURIZATION
Ultra-thin and compact designs are a hallmark of next-generation flexible circuits. These attributes provide greater flexibility and ease of navigation while expanding functionality in minimally invasive applications, where every millimeter counts.
SEAMLESS SENSOR INTEGRATION
Modern flexible circuits allow for the seamless incorporation of advanced sensors. This enables real-time monitoring, diagnostics, and data collection directly at the point of care and capabilities that can meaningfully improve procedural outcomes and patient safety.
ENHANCED FUNCTIONALITY
Engineered to withstand the demanding conditions of catheter use, these circuits combine mechanical flexibility and dynamic movement with long-term reliability. The result is devices that perform consistently even in prolonged or high-stress procedures.