Endoscope Flexible Circuits

Enhancing endoscope performance with flexible circuits

There is significant momentum behind the adoption of flexible circuits in the medical field, driven by the growing demand for advanced catheter-based technologies. These solutions enable minimally invasive procedures across a wide range of applications, including ablation, electrophysiology studies, cardiac mapping and diagnostics, angioplasty, stent deployment, and beyond.

Flexible circuits are playing an increasingly important role in modern medical devices by improving precision, reliability, and functionality in space-constrained environments.

Endoscope_medical
Endoscope Specifications

ITEMSMASS PRODUCTION
Layer1-6L
ThicknessMulti-layer board according to customer requirements
Single sided board: 0.065mm MIN
Double-sided board: 0.125mm MIN
OutlineLength: single/double/multi-layer: 1.45m MAX *
Width: single/double/multi-layer: 0.5mm - 0.8mm MIN *
Multi-layer: 1.0mm MIN *
*The data obtained from the average calculation according to the wiring of the product
OptionsShield Film: (thickness: 16um, 20um)
FR4 (0.1-0.5mm)
PI stiffener (0.075-0.225mm)
Metallic stiffener (0.1-0.3mm)
Min. Conductor Width & SpacingSingle and double sided circuit: 0.05mm
Multi-layered circuit: 0.075mm
Alignment Tolerance Between Layers0.05mm
Conductor To OutlineSingle and double sided circuit: >0.10mm
Multi-layer circuit: >0.15mm
PAD To Outline0.2mm MIN
Min. Hole SizeLaser drill: Ø0.05mm
Mechanical drill PTH: Ø0.1mm
Copper Plating Thickness10-15um (hole)
Min. Coverlay Openings0.50mm
Min. Coverlay Web0.30mm
Min. Solder Mask Opening0.20-0.30mm
Min. Solder Mask Web0.10mm
Max. Panel Size≤250*1500mm (single/double/multi-layer)
Final FinishENIG (NI:2-6um AU:0.05-0.09um)
Electroplated hard gold (NI:2-6um AU:0.1-1.0um)
Electroplated soft gold (NI:2-6um AU:0.1-1.0um)
Trim MethodLaser (outline<1mm)
Tooling (Outline>1mm)-- tooling costs ≥ $4k
Impedence RequirementDifferential impedance: 100ohms+/-10%

catheter second image-web

Features

PRECISION & RELIABILITY

Flexible circuits enhance catheter performance by delivering superior movement control, durability, and consistent operation during complex medical procedures. Their ability to maintain integrity under repeated flexing and in challenging anatomical environments helps physicians achieve greater procedural accuracy and safety.

MINIATURIZATION

Ultra-thin and compact designs are a hallmark of next-generation flexible circuits. These attributes provide greater flexibility and ease of navigation while expanding functionality in minimally invasive applications, where every millimeter counts.

SEAMLESS SENSOR INTEGRATION

Modern flexible circuits allow for the seamless incorporation of advanced sensors. This enables real-time monitoring, diagnostics, and data collection directly at the point of care and capabilities that can meaningfully improve procedural outcomes and patient safety.

ENHANCED FUNCTIONALITY

Engineered to withstand the demanding conditions of catheter use, these circuits combine mechanical flexibility and dynamic movement with long-term reliability. The result is devices that perform consistently even in prolonged or high-stress procedures.

Download our Design Guide, which includes
Product Design Information, Quoting and Shipping/Packaging Options

Request a Quote

Our team is ready to connect and discuss your needs, no matter the application.
Request a quote today to share your ideas and
take the first step toward bringing your project to life.